Calibration Hydrophone and HIFU (Primary)
Sensitivity and phase determination, amplitude calibration, and measurement of the effective radius for directional applications
- Description
- Pulse calibration hydrophone
- TimeDelay calibration hydrophone
- HIFU pulse calibration
- HIFU intensity test
The Primary Calibration service is arranged and managed by our expert team, with the calibration performed by PTB (Physikalisch-Technische Bundesanstalt), Germany’s national metrology institute. Using reference transducers and well-established methods, PTB provides high-accuracy sensitivity calibration. Calibration services are available across different range of frequencies, with different calibration options available depending on your specific needs. Whether you’re working with new or critical hydrophones, this service ensures traceable, reliable data. It is offered as an option when purchasing our hydrophones, giving you the flexibility to choose the most suitable frequency range for your application.
VK-14025
Hydrophone amplitude and phase 0.1 – 100 MHz
- Sensitivity calibration of a hydrophone
- Determination of Sensitivity amplitude and phase
- Frequency range: 0.1-100 MHz
- in accordance with IEC 62127-2 standards
(You will receive the data file and a calibration certificate.)
VK-14025
Hydrophone amplitude 1 – 40 MHz
- sensitivity calibration of a hydrophone
- determination of Sensitivity (Amplitude Only)
- frequency range: 1- 40 MHz
- in accordance with IEC 62127-2 standards
VK-140252
Hydrophone phase 1 – 40 MHz
- calibration of phase for membrane hydrophone
- phase response measurements
- frequency range: 1- 40 MHz
- in accordance with IEC 62127-2 standards;
VK-140251
Hydrophone radius 1 – 40 MHz
- effective radius determination for membrane hydrophone
- directional response measurements
- two axis, +/- 25 deg., @ 5, 10, 15, 20 MHz
- in accordance with IEC 62127-2 standards
VK-12025
Hydrophone sensitivity 1 – 20 MHz
- sensitivity calibration of a hydrophone
- determination of sensitivity (amplitude only)
- frequency range: 1 – 20 MHz
- in accordance with IEC 62127-2 standards
VK-12005
Hydrophone sensitivity 0.5 – 5 MHz
- sensitivity calibration of a membrane hydrophone
- determination of Sensitivity (amplitude only)
- frequency range: 0.5 – 5 MHz
- in accordance with IEC 62127-2 standards
VK-21100
HIFU Calibration – Broadband Primary Calibration according to PTB Standard
Service of the National Metrology Institute
Our HIFU calibration provides precise and traceable measurements of HIFU hydrophones in the frequency range from 0.1 to 100 MHz. Calibration is performed in 100 kHz increments and includes both amplitude and phase determination in compliance with the guidelines of the Physikalisch-Technische Bundesanstalt (PTB).
Scope of Services:
- Broadband primary calibration of the HIFU membrane hydrophone
- Determination of phase response across the full frequency range
- Performance testing of the HIFU hydrophone
- Waveform measurements at 1.06 MHz and 3.32 MHz
- Data deconvolution and determination of the minimum detectable pressure
- Delivery of a complete data file and calibration report
This calibration ensures maximum accuracy and traceability – ideal for research, development, and quality assurance in the field of High Intensity Focused Ultrasound (HIFU).
HIFU hydrophone intensity test neg. 10 – 80 Mpa