High-resolution ultrasonic measurement system for ultrasonic measurements using single-element transducers, Delivery includes manual, power cable, USB cable, software
Ultrasonic device for carrying out experiments on the subject of Doppler effect, fluid mechanics and Doppler sonography in vascular diagnostics, Delivery includes manual, power cable, USB cable, software
High-resolution ultrasonic measurement system based on the GS200 (article no. 10400) extended by an imaging module for ultrasonic measurements using single-element transducers and an ultrasonic array transducer Delivery includes ultrasonic…
NEW! Ultrasonic measurement system for generating ultrasonic images using the B-mode and M-mode methods with an ultrasonic array transducer Delivery includes ultrasonic array transducer, manual, power cable, USB cable, software
Realistic breast model with two fluid-filled, non-palpable cysts to carry out experiments on the subject of medical diagnostics (breast tumor diagnosis). For educational purposes only.
Realistic breast model with three malignant, palpable tumors to carry out experiments on the subject of medical diagnostics (breast tumor diagnosis). For educational purposes only.
Single-element transducer with a frequency of 1 MHz suitable for investigations with large penetration depths, equipped with special plug for connection to GAMPT-Scan or FlowDop
Single-element transducer with a frequency of 2 MHz suitable for investigations with medium penetration depths, equipped with special plug for connection to GAMPT-Scan or FlowDop
Single-element transducer with a frequency of 4 MHz suitable for detection of smallest structures, equipped with special plug for connection to GAMPT-Scan or FlowDop
Single-element transducer with a frequency of 1 MHz suitable for investigations with large penetration depths, equipped with BNC connector for universal use
Single-element transducer with a frequency of 2 MHz suitable for investigations with medium penetration depths, equipped with BNC connector for universal use
Single-element transducer with a frequency of 1 MHz suitable for investigations with large penetration depths, equipped with special plug for connection to GS200, GS200i or FlowDop200
Single-element transducer with a frequency of 2 MHz suitable for investigations with medium penetration depths, equipped with special plug for connection to GS200, GS200i or FlowDop200
Single-element transducer with a frequency of 4 MHz suitable for detection of smallest structures, equipped with special plug for connection to GS200, GS200i or FlowDop200
Test block made of homogeneous, transparent acrylic including several groups of differently sized defects for teaching basics of echoscopic investigations
Polyoxymethylene (POM) material sample including holder for determination of elastic material constants, extension for shear wave set (article no. 10218)
Realistic silicone breast model with two palpable occlusions simulating benign tumors to carry out experiments on the subject of medical diagnostics (breast tumor diagnosis). For educational purposes only
Aluminium test block with different reflector types for locating of discontinuities using techniques such as the echo, delta, tandem, transfer and angle techniques
Acousto-electric transducer for investigating characteristics of sound field of an ultrasonic probe equipped with special plug for connection to the echoscope GS200 / GS200i
Acousto-electric transducer for investigating characteristics of sound field of an ultrasonic probe equipped with special plug for connection to an echoscope
Acousto-electric transducer for investigating characteristics of sound field of an ultrasonic probe equipped with special plug for connection to the echoscope (GAMPT-Scan)
Set including a hydrophone for connection to echoscope GS200 / GS200i, holders and sample reservoir to carry out experiments investigating ultrasound propagation phenomena and sound fields
Set including a hydrophone for connection to an echoscope, holders and sample reservoir to carry out experiments investigating ultrasound propagation phenomena and sound fields
Set including a hydrophone for connection to echoscope (GAMPT-Scan), holders and sample reservoir to carry out experiments investigating ultrasound propagation phenomena and sound fields
Set including various Lamb wave combinations for investigating the frequency-dependent propagation velocity of ultrasonic waves in a thin glass plate (Lamb waves)
Sample reservoir with adjustments, ultrasonic multifrequency probe and laser module for exact positioning of the components for the generation of standing waves during the Debye-Sears experiment
Cover for sample reservoir (article no. 20225) to prevent change in the concentration of the liquid when using more than one reservoir at the same time
Sample reservoir made of glass with fixed laser and lens support offers optimal conditions for sound reflection for the production of standing waves and radiography with laser light, suitable for…
Absorbermat made of special silicone material for the prevention of undesired sound reflections in the AOM experiments or when using the thermoacoustic sensor, dimensions: 110 mm x 90 mm
Photodiode receiver with built-in amplifier for quantitative recording of the intensity of the laser light, Delivery includes power supply and BNC connection cable
Measuring unit with sensor and measuring amplifier for determining the local average intensity of ultrasonic waves, Delivery includes connection cables for a voltmeter
Electric stirrer to prevent the formation of local temperature differences and easier manufacturing of homogeneous solutions for concentration measurements, equipped with connection to the cw ultrasonic generator SC600 (article no.…
Ultrasonic pen shaped Doppler probe with a frequency of 2 MHz for measurements on the arm phantom (article no. 50160) equipped with special plug for connection to FlowDop200
Ultrasonic pen shaped Doppler probe with a frequency of 2 MHz for measurements on the arm phantom (article no. 50160) equipped with special plug for connection to FlowDop
Scanner system with sample holder and two step motors with exact angle positioning necessary for the rotation and linear shifting of the test sample to carry out experiments on the…
Realistic model of a human arm with integrated vessels and a stenosis for carrying out experiments on the subject of Doppler sonography in vascular diagnostics
Modified blood pressure cuff adapted to the arm phantom (article no. 50160) for experiments on blood pressure measurement with the ultrasonic Doppler method
Control unit for the CT scanner (article no. 60200) for software-aided or manual control of the scanner with connection to the ultrasonic echoscope GS200/GS200i
Acrylic measuring reservoir for CT scanner (article no. 60200) with built-in support for several ultrasonic transducers, dimensions: 430 mm x 150 mm x 150 mm
Test cylinder made of black opaque plastic with built-in structures of different absorption and sound velocity distributions to carry out experiments on the subject of ultrasonic tomography
This website uses cookies. If you continue to use the website, we will assume your consent. We collect anonymized data to analyze visitor behavior. You can find an opt-out in our privacy policy.OKPrivacy Policy